{"id":776,"date":"2021-09-17T20:59:25","date_gmt":"2021-09-17T18:59:25","guid":{"rendered":"http:\/\/galaxy.agh.edu.pl\/~madejski\/?page_id=776"},"modified":"2021-09-17T21:29:21","modified_gmt":"2021-09-17T19:29:21","slug":"model-of-a-steam-power-plant-exercise-1","status":"publish","type":"page","link":"https:\/\/galaxy.agh.edu.pl\/~madejski\/model-of-a-steam-power-plant-exercise-1\/","title":{"rendered":"Model of a steam power plant &#8211; exercise 1"},"content":{"rendered":"\n<p><strong>Purpose of the exercise<\/strong><br>To gain knowledge about the Ebsilon\u00ae Professional program environment and to develop a condensing steam power plant model allowing for calculations and determination of basic Rankine cycle parameters for defined input data.<\/p>\n\n\n\n<p><strong><strong>Description of tasks to be performed<\/strong><\/strong><br>To perform the exercise, a model of a condensing steam power plant need to be prepared according to the diagram shown in Figure 1. The model should contain the following elements: boiler, control valve, steam turbine, condenser, pump and generator. The input data are shown in Table 1.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"606\" height=\"326\" src=\"http:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-16.png\" alt=\"\" class=\"wp-image-782\" srcset=\"https:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-16.png 606w, https:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-16-300x161.png 300w\" sizes=\"auto, (max-width: 606px) 100vw, 606px\" \/><figcaption><strong>Figure 1. <\/strong>Model of the steam power plant<\/figcaption><\/figure>\n\n\n\n<p class=\"has-text-align-center\"><strong>Table 1.<\/strong> Input data for the power plant model<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\"><strong>Parameter<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>Value<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>Unit<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>Component number<\/strong><\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">Live steam temperature<\/td><td class=\"has-text-align-center\" data-align=\"center\">535.00<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u00b0C<\/td><td class=\"has-text-align-center\" data-align=\"center\">5<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Live steam pressure<\/td><td class=\"has-text-align-center\" data-align=\"center\">12.75<\/td><td class=\"has-text-align-center\" data-align=\"center\">MPa<\/td><td class=\"has-text-align-center\" data-align=\"center\">5<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Inlet pressure (nominal)<\/td><td class=\"has-text-align-center\" data-align=\"center\">12.40<\/td><td class=\"has-text-align-center\" data-align=\"center\">MPa<\/td><td class=\"has-text-align-center\" data-align=\"center\">6<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Mass flow start value<\/td><td class=\"has-text-align-center\" data-align=\"center\">650.00<\/td><td class=\"has-text-align-center\" data-align=\"center\">t\/h<\/td><td class=\"has-text-align-center\" data-align=\"center\">46<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Condenser steam inlet pressure<\/td><td class=\"has-text-align-center\" data-align=\"center\">4.20<\/td><td class=\"has-text-align-center\" data-align=\"center\">kPa<\/td><td class=\"has-text-align-center\" data-align=\"center\">46<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Condenser Upper terminal temperature difference<\/td><td class=\"has-text-align-center\" data-align=\"center\">3.50<\/td><td class=\"has-text-align-center\" data-align=\"center\">K<\/td><td class=\"has-text-align-center\" data-align=\"center\">7<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Isentropic efficiency<\/td><td class=\"has-text-align-center\" data-align=\"center\">88.00<\/td><td class=\"has-text-align-center\" data-align=\"center\">%<\/td><td class=\"has-text-align-center\" data-align=\"center\">6<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Mechanical efficiency<\/td><td class=\"has-text-align-center\" data-align=\"center\">99.80<\/td><td class=\"has-text-align-center\" data-align=\"center\">%<\/td><td class=\"has-text-align-center\" data-align=\"center\">6<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Generator efficiency<\/td><td class=\"has-text-align-center\" data-align=\"center\">98.00<\/td><td class=\"has-text-align-center\" data-align=\"center\">%<\/td><td class=\"has-text-align-center\" data-align=\"center\">11<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p><strong>Uwaga:  <\/strong>In the version Ebsilon\u00ae Professional 15 (or higher), to avoid the \u2018Missing frequency\u2019 error in the electric lines, change the Iteration report error option to \u2018No\u2019. To do so, go to option <em>Extras <\/em>\u2192 <em>Model Options<\/em> \u2192 <em>Iteration<\/em> \u2192 Select Nie (:0) for <em>Report errors in the system of equations also for shafts and electric lines<\/em> and click OK<\/p>\n\n\n\n<p><strong>Exercise modeling procedure<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\"><li>. Open Ebsilon\u00aeProfessional, save the file as Steam_Plant_model.ebs.<\/li><\/ol>\n\n\n\n<ol class=\"wp-block-list\" start=\"2\"><li>Select and place the following components on the work area:<br>\u2013 Steam generator \u2013 Comp 5,<br>\u2013 Control valve \u2013 Comp 14,<br>\u2013 Steam turbine \u2013 Comp 6,<br>\u2013 Condenser \u2013 Comp 7,<br>\u2013 Pump \u2013 Comp 8,<br>\u2013 Motor \u2013 Comp 29,<br>\u2013 Generator \u2013 Comp 11.<\/li><li>Connect the selected components in the correct order as shown in the diagram in Figure 1.<\/li><li>Supplement the model with elements allowing for entering input data:<br>a) Place the Measuring point (Comp 46) component at the outlet steam line from the boiler. Inside the component, in the Type of MEASM (FTYP) field, select the Mass flow: 4 option, and then in the Measured or start value (MEASM) field, enter the value 650 t \/ h (Fig. 2).<\/li><\/ol>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-2-1024x726.png\" alt=\"\" class=\"wp-image-710\" width=\"1024\" height=\"726\" srcset=\"https:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-2-1024x726.png 1024w, https:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-2-300x213.png 300w, https:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-2-768x545.png 768w, https:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-2.png 1049w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption><strong>Figure 2. <\/strong>Component 46 with the input data<\/figcaption><\/figure><\/div>\n\n\n\n<p class=\"has-text-align-center\"><\/p>\n\n\n\n<p>b) Using the Measuring point (Comp 46) component, set the turbine outlet pressure at the Steam outlet line to 4.2 kPa.<br>c) Additionally, on the Extraction 1 line from the steam turbine, place the component General input value \/ start value (Comp 33). Enter 0.0 kg \/ s in the Mass flow field (Fig. 3).<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1007\" height=\"724\" src=\"http:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-3.png\" alt=\"\" class=\"wp-image-714\" srcset=\"https:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-3.png 1007w, https:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-3-300x216.png 300w, https:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-3-768x552.png 768w\" sizes=\"auto, (max-width: 1007px) 100vw, 1007px\" \/><figcaption><strong>Figure 3.<\/strong> Component 33 with the input data<\/figcaption><\/figure><\/div>\n\n\n\n<p>d) To input the cooling water parameters at the condenser inlet, select the component Boundary value (Comp 1) and connect it to the Cooling medium inlet line in the condenser component. Enter a value of 2.0 bar in the Pressure field and a value of 15.0 \u00b0 C in the Temperature field (Fig. 4).<br>e) Complete the model with the values \u200b\u200bof temperature (Main steam temperature) and pressure (Main steam pressure) in the boiler component (Fig. 5), according to the data presented in table 1. Additionally, make sure that in the Specification and Handling of spray fields and blow down flows the options with index 0 are active.<\/p>\n\n\n\n<ol class=\"wp-block-list\" start=\"5\"><li>The remaining input data for the model should be defined using the components and methods presented in point 4, as summarized in Table 1. The last column of the table contains the names of components in which the indicated values \u200b\u200bshould be entered. Figure 6 shows the model with the elements that allow for entering and changing the input data.<\/li><li>In the turbine component, define the method of calculations &#8211; in the Inlet pressure handling field, select the option P1 calculated from P1NSET (by Stodola equation): 0 (Fig. 7). Additionally, in the field Inlet pressure (nominal), enter the value of the main steam pressure after the control valve to the turbine in accordance with Table 1.<\/li><\/ol>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"974\" height=\"696\" src=\"http:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-4.png\" alt=\"\" class=\"wp-image-722\" srcset=\"https:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-4.png 974w, https:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-4-300x214.png 300w, https:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-4-768x549.png 768w\" sizes=\"auto, (max-width: 974px) 100vw, 974px\" \/><figcaption><strong>Figure 4. <\/strong>Component 1 and the input data for calcualtions<\/figcaption><\/figure><\/div>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"957\" height=\"683\" src=\"http:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-5.png\" alt=\"\" class=\"wp-image-723\" srcset=\"https:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-5.png 957w, https:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-5-300x214.png 300w, https:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-5-768x548.png 768w\" sizes=\"auto, (max-width: 957px) 100vw, 957px\" \/><figcaption><strong>Figure 5.<\/strong> Component 5 with the input data for calculations<\/figcaption><\/figure><\/div>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-6.png\" alt=\"\" class=\"wp-image-725\" width=\"876\" height=\"682\" srcset=\"https:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-6.png 876w, https:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-6-300x234.png 300w, https:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-6-768x598.png 768w\" sizes=\"auto, (max-width: 876px) 100vw, 876px\" \/><figcaption><strong>Figure 6.<\/strong> Model with all components that allow to definie input data <\/figcaption><\/figure><\/div>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"974\" height=\"696\" src=\"http:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-7.png\" alt=\"\" class=\"wp-image-728\" srcset=\"https:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-7.png 974w, https:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-7-300x214.png 300w, https:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-7-768x549.png 768w\" sizes=\"auto, (max-width: 974px) 100vw, 974px\" \/><figcaption><strong>Figure 7. <\/strong>Component of steam turbine &#8211; selection of  the caclulation method<\/figcaption><\/figure><\/div>\n\n\n\n<p>7. In the condenser component, in the Design specification for vapor pressure field, select Design vapor pressure given externally (in off design as start value): \u20131 as described in Figure 8.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1018\" height=\"732\" src=\"http:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-8.png\" alt=\"\" class=\"wp-image-731\" srcset=\"https:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-8.png 1018w, https:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-8-300x216.png 300w, https:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-8-768x552.png 768w\" sizes=\"auto, (max-width: 1018px) 100vw, 1018px\" \/><figcaption><strong>Figure 8.<\/strong> Component of condenser \u2013 selection of calculation method <\/figcaption><\/figure><\/div>\n\n\n\n<p>8. Save the file with the developed model (Steam_Plant_model.ebs).<\/p>\n\n\n\n<p>9. Supplement the model with elements enabling the visualization and presentation of selected parameters in characteristic points of the model circulation. To do this, select the Insert value-cross option from the toolbar and then indicate the line for which the parameter values \u200b\u200bwill be displayed. By default, values \u200b\u200bfor pressure, temperature, specific enthalpy and mass flow are displayed. The range of the presented parameters can be changed by double-clicking on the data table, then go to the Values \u200b\u200btab. In the area marked in Figure 9, it is possible to add new or change the range of current parameters of a given line, which are presented in the model. Parameters can be selected from the list that expands after clicking in the Name column. Additionally, you can select the unit that should be displayed for a given parameter by expanding the list in the Unit column, and also activate the Unit option in the Show area. Using the Insert value-cross option, select the parameters of temperature, pressure, specific enthalpy and mass flow at characteristic points of the circulation, as shown in the diagram in Figure 9 (note: the values \u200b\u200bwill only be displayed after the first calculations &#8211; see point 10). Display parameter values \u200b\u200bwith the appropriate units (e.g. MPa, kJ \/ kg, \u00b0 C, kg \/ s).<\/p>\n\n\n\n<p>10. Perform calculations by running the simulation with the Simulation button or with the F9 key and verify the obtained results with the values \u200b\u200bpresented in Figure 10. For the analyzed case, a message will appear informing about excess information about mass flow in the circulation &#8211; Overdetermination in 45 mass flow. In order to eliminate this error, an additional component, Separator (logical) &#8211; Comp 80, should be introduced into the model and placed on the feed water line before the boiler component (Fig. 10). Inside the separator component, select Mass flow: 4 in the Type of separation (FSPEC) field (Fig. 11). Details of errors in the model can be checked by selecting the Calculations tab on the toolbar, and then Error Analysis.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1014\" height=\"717\" src=\"http:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-9.png\" alt=\"\" class=\"wp-image-733\" srcset=\"https:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-9.png 1014w, https:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-9-300x212.png 300w, https:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-9-768x543.png 768w\" sizes=\"auto, (max-width: 1014px) 100vw, 1014px\" \/><figcaption><strong>Figure 9. <\/strong>Insert value-cross option \u2013 defining of the results presentation form<\/figcaption><\/figure><\/div>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"994\" height=\"572\" src=\"http:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-10.png\" alt=\"\" class=\"wp-image-734\" srcset=\"https:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-10.png 994w, https:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-10-300x173.png 300w, https:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-10-768x442.png 768w\" sizes=\"auto, (max-width: 994px) 100vw, 994px\" \/><figcaption><strong>Figure 10. <\/strong>Model of steam power plant with calculation results<\/figcaption><\/figure><\/div>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"742\" src=\"http:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-11-1024x742.png\" alt=\"\" class=\"wp-image-735\" srcset=\"https:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-11-1024x742.png 1024w, https:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-11-300x217.png 300w, https:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-11-768x556.png 768w, https:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-11.png 1084w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption><strong>Figure 11.<\/strong> Component 80 \u2013 selection of logical separation option<\/figcaption><\/figure><\/div>\n\n\n\n<ol class=\"wp-block-list\" start=\"11\"><li>Save the file with the model and calculation results (Steam_Plant_model.ebs).<\/li><li>View the output at the generator terminals, the pump power, and the useful boiler heat output using the Insert Value-Cross option. NOTE: In order to enter an Insert Value-Cross marker on a given line, it must be extended. In the program, the power is marked with the letter Q. Additionally, in the Value field properties tab, select a yellow background &#8211; select the Fill option and then select a color. Compare your results with the results shown in Figure 10.<\/li><li>Create new calculation profiles to simulate the operation of the condensing plant in the off-design mode, which represents the operation of the system under load conditions other than the rated load. To do this, on the toolbar, select the Edit profiles option, then New sub profile and after double-clicking on the newly created profile, change its name to LOAD_90 (Fig. 12). Repeat these steps and create two additional profiles LOAD_80 and LOAD_70. In off-design profiles, the amount of flowing steam should be defined at the level of 90% (LOAD_90), 80% (LOAD_80) and 70% (LOAD_70) of the nominal boiler capacity equal to 650 t \/ h. Enter the value of the fresh steam flow at component 46 on the fresh steam line from the boiler (see point 4a).<\/li><\/ol>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1025\" height=\"733\" src=\"http:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-12.png\" alt=\"\" class=\"wp-image-738\" srcset=\"https:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-12.png 1025w, https:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-12-300x215.png 300w, https:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-12-768x549.png 768w\" sizes=\"auto, (max-width: 1025px) 100vw, 1025px\" \/><figcaption><strong>Figure 12. <\/strong>Profile definition window for off-design mode<\/figcaption><\/figure><\/div>\n\n\n\n<ol class=\"wp-block-list\" start=\"14\"><li>Perform calculations for all defined calculation profiles (Design, LOAD_90, LOAD_80 and LOAD_70), and export the results for individual variants using the EBShtml function (File \u2192 Export \u2192 EBShtml).<\/li><li>Save the final version of the file (Steam_Plant_results.ebs).<\/li><\/ol>\n\n\n\n<p><strong>Additional task<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\"><li>Calculate the energy efficiency of the cycle for all analyzed operating profiles of the condensing plant. To do this, use the Cycle efficiency meter (Comp 32) component, place it in the Design profile and configure it accordingly. Particular attention should be paid to the appropriate way of connecting the ports of this component &#8211; connect the Useful power port 1 with the electric power line from the generator, and the Expenditure port 2 (Sensible heat) with the logical line containing the useful power transmitted in the boiler. In the other off-design profiles, this component will be automatically entered. In component 32, select percent as the unit of efficiency. Compare the results with the results presented in Figure 13. Export the results using the EBShtml function.<\/li><li>Present the results on the temperature-entropy diagram (Fig. 14). To do this, select the Extras tab on the toolbar, then Diagrams, <em>T-s<\/em> Diagram and the Complete option. In the Profiles field, select all the created calculation profiles.<\/li><li>Export the results using the EBShtml function. Save the file as Steam_Plant_additional_task.ebs.<\/li><\/ol>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"619\" src=\"http:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-13-1024x619.png\" alt=\"\" class=\"wp-image-739\" srcset=\"https:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-13-1024x619.png 1024w, https:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-13-300x181.png 300w, https:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-13-768x464.png 768w, https:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-13.png 1044w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption><strong>Figure 13. <\/strong>Model of steam power platn together with component 32 (Design mode)<\/figcaption><\/figure><\/div>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"599\" src=\"http:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-14-1024x599.png\" alt=\"\" class=\"wp-image-740\" srcset=\"https:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-14-1024x599.png 1024w, https:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-14-300x175.png 300w, https:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-14-768x449.png 768w, https:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/obraz-14.png 1028w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption><strong>Figure 14. <\/strong>Graph in T-s system for analyzed steam power plant<\/figcaption><\/figure><\/div>\n\n\n\n<p><strong>Summary<\/strong><br>The task was to familiarize the user with the Ebsilon\u00ae Professional program environment and to develop the first simulation model of a condensing steam power plant. The user knows how to identify components, connect them correctly, build the full structure of the simulation model and enter input data with a graphical presentation of selected calculation results.<\/p>\n\n\n\n<p>Below are the solutions for the condensing steam power plant model presented in exercise 1, developed on the basis of the book:<\/p>\n\n\n\n<p>Madejski P., \u017byme\u0142ka P., <em><strong><a rel=\"noreferrer noopener\" href=\"https:\/\/www.ibuk.pl\/fiszka\/234995\/wprowadzenie-do-komputerowych-obliczen-symulacji-pracy-systemow-energetycznych-w-programie-steag-ebsilon.html\" target=\"_blank\">Wprowadzenie do komputerowych oblicze\u0144 i symulacji pracy system\u00f3w energetycznych w programie STEAG Ebsilon\u00aeProfessional<\/a><\/strong> (Introduction to computations and simulations of energy systems operation using STEAG Ebsilon\u00ae Professional software])<\/em>. Wydawnictwa AGH, Krak\u00f3w 2020<\/p>\n\n\n\n<p><a rel=\"noreferrer noopener\" href=\"http:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/Silownia_Parowa_wyniki.htm\" target=\"_blank\">Steam_Plant_results<\/a><\/p>\n\n\n\n<p><a rel=\"noreferrer noopener\" href=\"http:\/\/galaxy.agh.edu.pl\/~madejski\/wp-content\/uploads\/2021\/09\/Silownia_Parowa_zadanie_dodatkowe.htm\" target=\"_blank\">Steam_Plant_additional_task<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Purpose of the exerciseTo gain knowledge about the Ebsilon\u00ae Professional program environment and to develop a condensing steam power plant model allowing for calculations and determination of basic Rankine cycle parameters for defined input data. Description of tasks to be performedTo perform the exercise, a model of a condensing steam power plant need to be <a class=\"read-more\" href=\"https:\/\/galaxy.agh.edu.pl\/~madejski\/model-of-a-steam-power-plant-exercise-1\/\">READ MORE<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-776","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/galaxy.agh.edu.pl\/~madejski\/wp-json\/wp\/v2\/pages\/776","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/galaxy.agh.edu.pl\/~madejski\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/galaxy.agh.edu.pl\/~madejski\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/galaxy.agh.edu.pl\/~madejski\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/galaxy.agh.edu.pl\/~madejski\/wp-json\/wp\/v2\/comments?post=776"}],"version-history":[{"count":12,"href":"https:\/\/galaxy.agh.edu.pl\/~madejski\/wp-json\/wp\/v2\/pages\/776\/revisions"}],"predecessor-version":[{"id":799,"href":"https:\/\/galaxy.agh.edu.pl\/~madejski\/wp-json\/wp\/v2\/pages\/776\/revisions\/799"}],"wp:attachment":[{"href":"https:\/\/galaxy.agh.edu.pl\/~madejski\/wp-json\/wp\/v2\/media?parent=776"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}